Cold
This test serves to demonstrate that under the influence
of cold no damage is caused to the equipment under
test and no permanent or temporary malfunctions occur.
5.1 Test procedure
Basis: IEC publication 60068-2-1
– Test A): for products inside the ship
– Test B): for products on the open deck or in
cold areas.
5.2 Test conditions
The functional tests are performed at the rated operational
voltage Ue.
Damp heat
This test serves to demonstrate that under the influence
of damp heat no damage is caused to the equipment
under test and no permanent or temporary malfunctions
occur.
7.1 Test procedure
Basis: IEC publication 60068-2-30
– Test Db
7.2 Test conditions
The functional tests are performed at the rated operational
voltage Ue.