IEC 60529 First Characteristic Numeral Degrees of Protection - Water

INDOOR

 

IP X1 Vertical Falling Drops           10 Min. Drip Test                              Limited Water Inside;

Not on Live Parts

 

IP X2 15° Vertical Falling Drops    10 min. 15° Drip Test                       Limited Water Inside;

Not on Live Parts

 

IP X3 Spraying Water                      5 min. 120° Oscillating Tube or

5 min. Partial Spray

Limited Water Inside;

Not on Live Parts

 

IP X4 Splashing Water                    10 min. 360° Oscillating Tube

or 5 Min. Full Spray

Limited Water Inside;

Not on Live Parts

 

IP X5 Waterjets                                                 Fire Hose 3.3 gal. (12.5L)/min      Limited Water Inside;

Not on Live Parts

 

OUTDOOR

 

IP X6 Powerful Waterjets             Fire Hose 26 gal. (100L)/Min.       Limited Water Inside;

Not on Live Parts

 

IP X7 Temporary Submersion at Limited Depth   Submerge 3 ft. (1m) – 30 Min.    Limited Water Inside;

Not on Live Parts

 

IP X8 Prolonged Submersion at  Limited Depth More Severe Than X7 Customer Agreement         Limited Water Inside;

Not on Live Parts